Create drivers license. NOTE: The Bransonic B-Series of ultrasonic cleaners have been discontinued.However, we have a huge installed base of machines, and thousands of users - so this page is provided as a reference for those who need help with their older units, or who wish to upgrade.Branson B-Series Ultrasonic Manual Branson B-Series Liter. https://wareyellow937.weebly.com/download-unified-remote-for-mac.html. I too have a Branson ultrasonic cleaner that no longer works. I called Branson and they wanted something like $200 for the repair/schematic manual. No wonder all the American manufacturers are going out of business. Their customer support sucks. Blufftitler project files for electric guitar. Couldn't cost more then $20 to photocopy it and have someone put it in an envelope. Quick Answers Branson 8800 Ultrasonic cleaner, 5.5 gallon, 40 kHz Tank is 19.5'l x 11.5'w x 6'd Ships from stock Free US48 Ground shipping Returns accepted of unused tanks within 15 days Two year Factory Warranty, parts & labor We are an authorized distributor of Branson Ultrasonics Features Branson 8800 ultrasoni. Operator’s Manual. The beatles greatest hits download zip. Warranty Ultrasonic Cleaners, when used in accordance with manufacturer’s. Dadali disaat sendiri mp3. At the back of this manual, for additional information. › Branson 2200 ultrasonic cleaner manual › Branson 1200 ultrasonic operator manual › Branson ultrasonics corporation › Branson 2510 sonicator manual › Branson 3210 ultrasonic cleaner manual. Gigayte z97 gaming 7 user manual. Ending time krishnamurti pdf. https://acmebrown920.weebly.com/how-to-download-winebottler-on-mac.html. Branson Ultrasonics: CPX Series. Bransonic.com The Bransonic digital ultrasonic bath is the only bath that is fully programmable.
- Forum Actions
- Quick Links
Likes: 6
Thread Tools
Display
- Diamond
- Join Date
- Jan 2002
- Location
- West Coast, USA
- Posts
- 7,470
- Post Thanks / Like
- Likes (Given)
- 456
- Likes (Received)
- 4950
I picked up a 5.5 gallon Branson ultrasonic cleaner in non-working condition. The heater is fine, but the ultrasonic is non-existent. All the unit does is lightly hum when the timer is on. Any idea how to troubleshoot or, better yet, repair this?
Couldn't find any help in the way of schematics or troubleshooting on the Web, other than a factory repair. Did open it up and there are no obviously friend components inside and the two fuses on the circuit are OK. - Diamond
- Join Date
- Feb 2006
- Country
- UNITED STATES
- State/Province
- Indiana
- Posts
- 12,724
- Post Thanks / Like
- Likes (Given)
- 635
- Likes (Received)
- 3690
I bought a new Branson ultrasonic cleaner years ago. After a while, the transducer, which was epoxied to the bottom of the tank, cracked and the wire came off. Branson said it could not be repaired and offered to sell me a new cleaner. So I bought a new L&R ultrasonic, which has worked fine for the last twenty years or so.
You must have water in the tank to test whether the unit is working prperly. Never run it dry.
Larry - Hot Rolled
- Join Date
- Aug 2002
- Location
- Carlsbad (San Diego), CA
- Posts
- 714
- Post Thanks / Like
- Likes (Given)
- 15
- Likes (Received)
- 4
I too have a Branson ultrasonic cleaner that no longer works. I called Branson and they wanted something like $200 for the repair/schematic manual. No wonder all the American manufacturers are going out of business. Their customer support sucks. Couldn't cost more then $20 to photocopy it and have someone put it in an envelope.
- Stainless
- Join Date
- Aug 2004
- Location
- So. Cal.
- Posts
- 1,488
- Post Thanks / Like
- Likes (Given)
- 0
- Likes (Received)
- 4
I have ten schematics for some Branson USCs. Basically the 1220, 2200, 3200-5200 and 8000 series. Lemme know if you want one of them. JRouche
- Stainless
- Join Date
- Mar 2007
- Location
- Far Northern California, USA
- Posts
- 1,290
- Post Thanks / Like
- Likes (Given)
- 264
- Likes (Received)
- 138
I fixed a couple of cleaners for my wifes work and they weren't hard. The circuits are very simple. I just opened them up and traced out the circuits in my notebook. I worked harder than I needed to figureing out the feed back paths in the oscilator as the it wasn't related to the problem but I finally figured it out.
Mine were smaller 250 watt units but there could be similarities so I'll post what I know and see if it helps. These units generate high voltages when on so be carefull. The output forms a resonant circuit with the transducers. Added capacitance on the output can cause spurious oscillations and damage the output transistors so don't probe there with anything but a high impeadance probe. I learned this the expensive way. My units had a fuse soldered onto the circuit board so check this. The unit first rectifies the AC so check the ouput of the diodes for about 250 VAC. This feeds a cascade pair of large FETS. If you have B++ and no output then the FETS are the likely suspect. My units used feedback from a small series transformer on the output to drive the FETS into oscillation. After the transformer was a large choke coil to resonate the transducers. The 250 W unit used two transducers connected in parallel. At the operating frequency the transducers look like a large lossy capacitor. Thats all the circuitry that was on the PCB. Very simple. Either there is an open somewhere, possible a loose wire, or one of the FETS is blown. Pretty simple.
starbolin - Engine Room ArtificerHot Rolled
- Join Date
- Feb 2007
- Location
- Gosport Hampshire UK
- Posts
- 546
- Post Thanks / Like
- Likes (Given)
- 0
- Likes (Received)
- 12
Coincidentally I took a brand new 5100 model out of the box on Tuesday last week which didn't work.
As you do, I looked at taking it apart but the big makers label on the front was stuck over two of the cover screws. So not wanting to screw up any warranty I called Branson, who in the UK no longer have anything to do with Ultrasonic, but have sold the rights on. The new company told me to send it straight back as this happens enough for the guy on the phone not to quibbble.
This model was made in Mexico.
Al - Hot Rolled
- Join Date
- Aug 2002
- Location
- Carlsbad (San Diego), CA
- Posts
- 714
- Post Thanks / Like
- Likes (Given)
- 15
- Likes (Received)
- 4
- Cast Iron
- Join Date
- Jan 2005
- Location
- Houston
- Posts
- 312
- Post Thanks / Like
- Likes (Given)
- 0
- Likes (Received)
- 0
These guys have repaired my Branson unit several times.
Very good service. (no affiliation, just a satisfied customer).
Alpha Omega Ultrasonics Corporation
2821 National Drive
Garland, TX 75041
Tel: 800-540-4967
Fax: 972-840-3668
They are one of many listed on the branson web site. - Diamond
- Join Date
- Feb 2005
- Location
- Birmingham, AL
- Posts
- 4,027
- Post Thanks / Like
- Likes (Given)
- 13
- Likes (Received)
- 49
- Hot Rolled
- Join Date
- Sep 2003
- Location
- South Carolina
- Posts
- 889
- Post Thanks / Like
- Likes (Given)
- 3
- Likes (Received)
- 79
I too have a partially functioning Branson - model 8200. When I turn on the power, the digital display scrolls from zero to 99 and one LED is illuminated but none of the controls works. Just by coincidence, I discovered that if I depress the start-stop button while the power is switched on, the cleaning circuitry works but not the heater or other mode controls.
So I know the transducer circuitry works but it sure would be nice to have the heater.
Like Pete, no visually obvious damage to the electronics and electrical troubleshooting is beyond my simple understanding. The external fuse is good - will check the circuit board for any thing looking like a fuse. I presume the control circuitry is defective. Any other suggestions for things to check?
Anyone possibly have a defective 8200 for parts?
JRouche, will send you a PM.
Thanks, Jim - Diamond
- Join Date
- Jan 2002
- Location
- West Coast, USA
- Posts
- 7,470
- Post Thanks / Like
- Likes (Given)
- 456
- Likes (Received)
- 4950
Thanks to all who responded, especially JRouche (pm sent) and Starbolin.
Metal_twister -- any idea of what your repairs have been costing? Are we talking sub-$200 or a few hundreds for your typical repair? I'd live with the smaller capacity of the tiny L&R I have that's working, rather than put too much into an apparently repair-prone Branson. - Stainless
- Join Date
- Aug 2004
- Location
- So. Cal.
- Posts
- 1,488
- Post Thanks / Like
- Likes (Given)
- 0
- Likes (Received)
- 4
- Cast Iron
- Join Date
- May 2003
- Location
- iowa
- Posts
- 448
- Post Thanks / Like
- Likes (Given)
- 0
- Likes (Received)
- 3
pete i have a brason it was bad i installed new trasistors in it 5.00 a pc and then found that you must tune the coil . by removing loops of wire to get max power what we did is hooed up to amp meter and removed or added coils till we had max amps out of unit .please do this dead the will buzz you bad. but my unit kicks but . enyone that has a larger unit thats dead and you want to get rid of it let me know im going to make a bad ass out of one bought a big set of transdusers and a power supply jim
- MitsTechStainless
- Join Date
- Feb 2006
- Country
- UNITED STATES
- State/Province
- New Jersey
- Posts
- 1,420
- Post Thanks / Like
- Likes (Given)
- 7
- Likes (Received)
- 46
These guys have repaired my Branson unit several times.Do you know if they will service any ultrasonic cleaner? I have an older, almost NOS Sonicor that died. It's a huge tank with a remote sonic generator. The generator appears dead. While they were very helpful on the phone as far as tech support (actually put me on with an Electical Engineer!) their overall answer was 'Can't get parts for it, maybe we can sell you a new generator?' (for $1,500 I'm sure!)
Very good service. (no affiliation, just a satisfied customer).
Alpha Omega Ultrasonics Corporation
2821 National Drive
Garland, TX 75041
Tel: 800-540-4967
Fax: 972-840-3668
They are one of many listed on the branson web site.
I'm sure it's nothing more than a few $5 parts from DigiKey but I'm no EE myself. I got a great deal on this unit and it worked when I bought it, but a month later when I got to hooking it up it was DOA for some reason. I'd REALLY like to get this unit running (about 20 gallons) but it certainly isn't worth a G-note plus to me at this point. - Cast Iron
- Join Date
- Jan 2005
- Location
- Houston
- Posts
- 312
- Post Thanks / Like
- Likes (Given)
- 0
- Likes (Received)
- 0
We have a 2 gallon and a 5 gallon Branson.
Alpha guys would turn it arournd in a day or two.
Seems like each time repairs were $140'sh?
I think they repair any brand cleaner.
Ours run 12 hours a day. We have found no brand to be better than any other. It's the nature of all those vibes to evientually play havoc on the electronics.
Go on the Branson sight there are many independant repair people listed. - Plastic
- Join Date
- Nov 2011
- Location
- Stellenbosch, South Africa
- Posts
- 1
- Post Thanks / Like
- Likes (Given)
- 0
- Likes (Received)
- 0
Schematic
Hi JRouche,
Please can you send me a schematic for the Branson 3200 - mine in the lab wont even switch on, so our on-site technicians are really going to need the schematics to troubleshoot and see if they can fix this one.
I am a lab manager in South Africa, so making use of Branson specialists isnt an option. my email is [email protected]
your help is greatly appreciated!
P Steyn - Aluminum
- Join Date
- Jan 2010
- Location
- Rochester, NY
- Posts
- 227
- Post Thanks / Like
- Likes (Given)
- 5
- Likes (Received)
- 10
We had a 10 year old Omega Sonics we use for carb cleaning that stopped this past year. After many phone calls we found these folks - Did what they said, when they said, for the price they said. Seems the tank drain is mounted right above the PCB and seeped fluid onto the board.
BRANSON ULTRASONICS PARAGON ELECTRONICS PARAGONFLA SALES SERVICE REPAIR.
Good Luck
bob - Plastic
- Join Date
- Jan 2012
- Location
- usa md
- Posts
- 4
- Post Thanks / Like
- Likes (Given)
- 0
- Likes (Received)
- 0
sonicor sc-400t11 or ii
does anyone have a wiring schematic for a sonicor sc400t11 or ii. it has a 5 gallon tank. when I got it 1 of the transducers had fallen off of the tank and blew the main resistors. I re mounted the transducer and replaced the resistors . I left the transducers dossconnected to see if there was still a short in the system and the main resistors popped.
- Plastic
- Join Date
- Jan 2012
- Location
- usa md
- Posts
- 4
- Post Thanks / Like
- Likes (Given)
- 0
- Likes (Received)
- 0
could you send me one of the diagrams that would be equal yo the 5 gallon sonicor sc-400t11 or ii. or if you have one for the sonicor that would be great.
thanx. - Aluminum
- Join Date
- May 2007
- Location
- indiana
- Posts
- 127
- Post Thanks / Like
- Likes (Given)
- 0
- Likes (Received)
- 18
I have always found the units made by Sonicor to outperform the ones from Branson on a watt by watt basis. As some of the other posters have done, I would pitch the defunct Branson and get another brand.
Ultrasonic Cleaner For Carburetors
GeneralTop- Site Areas
- Forums
- Manufacturing Today
- Specific Machine Forums
- Open Discussion
- Commerce
- Machinery Manual, Brochure and Photo Archives
- Forum features
«Previous Thread | Next Thread»
Bookmarks
Posting Permissions
- You may not post new threads
- You may not post replies
- You may not post attachments
- You may not edit your posts
Branson 5510 Ultrasonic Cleaner Manual
- BB code is On
- Smilies are On
- [IMG] code is On
- [VIDEO] code is On
- HTML code is Off